Miniatuur high-end spectroradiometer voor het meten van o.a.:

Verlichtingssterkte (van 10 tot 100.000 lux)

Kleurtemperatuur (correlated color temperature CCT in Kelvin)

Kleurweergave-index CRI en TM-30-15

Gamut Area Index GAI

Kleurcoördinaten CIE 1931, CIE 1960, CIE 1976

Irradiance Ee (W/m²)

Luminous Efficacy Ratio – LER

Photosynthetic photon flux density PPFD (μmol/m²s)

Flicker IEEE 1798 (index, %, Hz)

TLCI-2012 “Television Lighting Consistency Index”

Voldoet als luxmeter aan DIN 5032 deel 7 klasse B

2,1" kleurendisplay

4GB geheugen voor het opslaan van 500.000 metingen in CSV formaat

Uitvoerige functies via EXCEL sjabloon met macro's

USB 2.0 aansluiting
Interface en handleiding EN, DU, FR, IT, SP

Software Development Kit (SDK) via download

Productblad (PDF)


Offerte aanvragen Bestellen

Zien is geloven

De Mavospec Base is een meetinstrument met veel mogelijkheden. Wellicht meer dan u uit deze tekst kunt opmaken. Neem daarom gerust contact op voor een demonstratie.

Specificatie

  • Toepassing

    De Mavospec Base is een miniatuur high-end spectroradiometer voor dagelijkse metingen aan diverse conventionele en moderne lichtbronnen, zoals LEDs en OLEDs.


    Alle gemeten grootheden zoals verlichtingssterkte (lux), kleurtemperatuur (correlated color temperature CCT), kleurweergave-index CRI of Ra (R1-R15), kleurweergave conform TM-30-15, kleurcoördinaten conform diverse CIE normen, Flicker (%, frequentie), spectrale vermogensverdeling, piekgolflengte en dominante golflengte, coördinaten in CIE diagram, photosynthetic photon flux density PPFD, TLCI-2012 “Television Lighting Consistency Index”, worden vastgesteld voor het gemeten spectrum en weergegeven op een dusdanige heldere wijze dat experts, maar ook leken de resultaten kunnen begrijpen.


    Hierdoor kan de Mavospec Base Spectroradiometer gebruikt worden voor zeer uiteenlopende toepassingen zoals controle van een lichtontwerp, installatie en onderhoud van (verlichtings)systemen, R&D, productie en kwaliteitsborging van display panels, beoordelen van lichtbronnen en armaturen, het evalueren van tuinbouw (horticulture) toepassingen, televisie- c.q. opnamestudio’s, alsmede de evaluatie van ambient lichtparameters in psychologische en fysiologische onderzoeken.

  • Technische specificaties

    • Fabricaat: GOSSEN Foto- und Lichtmesstechnik GmbH, Nürnberg
    • Illuminance – Calculation of illuminance based on spectral data. Cosinecorrected measuring probe in accordance with class B per DIN 5032-7.
    • Large dynamic range – The meter is capable of measuring values from 10 to 100,000 lx, thus covering a broad range of applications.
    • Spectral power distribution – Measurement of spectral power distribution over a large spectral range of 340 to 750 nm with determination of the peak wavelength and dominant wavelength.
    • Chromaticity, color coordinates – Measurement of color coordinates in accordance with CIE 1931 [x,y], CIE 1960 [u,v] and CIE 1976 [u’, v’], and display of the CIE standard color table.
    • Light quality – Measurement of diverse parameters to indicate light quality such as:
    • Color Rendering Index – Measurement of the color rendering index CRI/Ra, averages from 1 to 8 indices and 1 to 15 indices, as well as individual indices R1 through R15.
    • IES TM-30-05 – Measurement of the color rendering according IES TM-30-15 with TM30  Rf  Fidelity Index and TM30 Rg Gamut Index.
    • Gamut Area Index – Measurement of the GAI.
    • Color temperature– Measurement of the (correlated) color temperature CTT in Kelvin.
    • Photosynthetic photon flux density PPFD – Measurement of photosynthetic photon flux density PPFD (μmol/m²s), PPFD (400…700 nm), PPFD_UV (380…400 nm), PPFD_Blue (400…500 nm), PPFD_Green (500…600 nm), PPFD_Red (600…700 nm), PPFD_FR (700…780 nm).
    • TLCI-2012 “Television Lighting Consistency Index” – Conform recommendation TLCI-2012 of The Technical Committee of the European Broadcasting Union (EBU), the colorimetric quality of lighting in the television production environment. New measured value window for TLCI (Television Lighting Consistency Index), Presentation of spectrum and reference spectrum, display of CCT, radiator type, Normalized distance to normalized color temperature, TLCI, — Colorist Advice Table: Sector, Lightness, Chroma, Hue — Qa Pie Chart: Presentation of TLCI values for specific Color Checker colors.
    • Flicker value – Measurement of Flicker value as index, percentage [%], frequency [Hz] and curve, Lightscope, IEEE 1789 rating.
    • LER – Luminous Efficacy of Radiation.
    • Outstanding measured value stability – The integrated temperature sensor and automatic temperature compensation of the dark stream assure outstanding measurement results over a large temperature range.
    • Calibration report – A simple calibration report is included in the scope of delivery.
    • Convenient daily use – Highly practical one-hand operation with the ring controller and just a few keys, easily legible color display with high resolution, compact design, protected transport in a high-quality aluminum case.
    • Automatic measured value storage – Thousands of light measurements can be automatically or manually saved in CSV format (approx. 2kB) to the 4 GB microSD card which is integrated into the battery compartment where it’s well protected.
    • Reference mode – For comparing two light sources or curves.
    • Easy data transfer – The integrated USB port permits easy data exchange with the PC (Windows and MS Excel needed). The data, which are saved in CSV format, can be imported to any desired programs.
    • Individual system integration – The open protocol for device control and data communication permits incorporation into the user’s own applications.
    • Sustainable device concept – The ability to update the device via the USB port keeps it open for future expansions and standards.
    • Ecological power supply – Replaceable, rechargeable lithium-ion battery, charging via USB port with external mains power pack, display of charging status and battery level, approximately 8 hours of continuous operation without shutdown.
    • Device control – Universal USB port for convenient data exchange, device control, firmware updates and battery charging
    • Individualized system integration – via open USB interface protocol
    • Sustainable device concept – thanks to update option via USB port
    • Extremely long rechargeable battery operating time – Can be extended by reducing display brightness, with automatic display and device shutdown.
    • 3-year guarantee
    • Afmetingen: 139 x 60 x 30 mm (H x B x D)
    • Gewicht: 200 gr
    • Levensduur accu: ≥ 8 u continu gebruik
    • Oplaadtijd: 1,5 u
  • Geheugen en rapportage

    Measured values can be saved in CSV format to the 4 GB microSD memory card integrated into the battery compartment either automatically for each measurement or manually by pressing a key. A new folder is created for each date and the filenames are based on the time of day. If the Mavospec Base Spectroradiometer is connected to the USB port at a PC, it appears as a disk drive and the measurement data can be transferred. CSV files can be read in to Excel directly (Macro’s needed), and can be further processed by the user in order to generate reports. A sample report is included in the scope of delivery and is located on the memory card.


    Diverse communication capabilities via USB support data transmission and control with external software, as well as integration into stationary measuring systems. The open communication protocol and an Excel application sample are also included on the memory card or can be requested by sending an e-mail to Lichtconsult.

  • Inclusief

    • Robuuste, aluminium koffer
    • Handige lichtgewicht draagetui met karabijnhaak en riemlus
    • Draagband
    • Oplaadbare accu Li-Ion
    • USB-kabel
    • Micro SD kaart 4 GB
    • Kalibreerprotocol ( E[lx] en CCT[K] )
    • Handleiding ENG-DU
    • Excel Template (Report & Datalogger)

Accessoires

Share by: